Paver Shield 260

Home :: Clear Coatings :: Paver Shield 260
Paver Shield 260
Paver Shield 260

Product Downloads

ACRYLIC CLEAR FINISH

A test patch is recommended to check for compatibility.

TUF-TOP PAVER SEALER is a high solids, low viscosity, Solvent based, 100 % Acrylic, non-yellowing "clear" coating for glazing and sealing bare and colored cement, concrete walks, concrete pavers and masonry. Paver Shield gives a medium to high gloss "wet" look that will withstand mild chemicals, grease, oil, and pick up from hot tires. Paver Sealer is formulated to be a maintainable finish, and may be easily re-applied to maintain wear areas and increase the overall life expectancy of the coating.

Paver Shield 260 is Best Used for

  • Brick and concrete pavers

    Brick and concrete pavers

  • Patios and walkways

    Patios and walkways

  • Concrete clear sealer

    Concrete clear sealer

  • Warehouse and garage floors

    Warehouse and garage floors

SKU PS260
Carrier
Compliance
Primer
Usage on Unpainted Surfaces
Use to Recoat H & C Stain
Solvent Based Acrylics
 
Our price:
Quantity
Compare product with:

Technical Information

Technical Data:

SOLIDS/WEIGHT22.5 %
COVERAGE125-250 sg.ft/gallon depending on porosity/texture of substrate
CLEAN-UPXYLENE/TOLUENE
VOC CONTENT676 G/L. / 5.64 LB./GAL.
APPEARANCEClear
LIGHT STABILITYExcellent
DURABILITYExcellent
TENSILE STRENGTHYExcellent
BONDINGGood
EPA AIM CATEGORYWater repellent sealer
WATER RESISTANCEExcellent
GASOLINE RESISTANCEFair
CHLORINE RESISTANCEGood
ANTI-FREEZE  Good
SOFT DRINKS, CITRUSGood
TANNING/BODY OILS  Good
C.O.F.*.62-.84

*Coefficient of friction will vary depending upon application, method film build, substrate profile, and surface contamination. Reference listed is over a smooth trowelled surface. Meets or exceeds the following test methods: G-23-F 2000 Hrs. / TT-C-555b No effect.

Usage Information

Preparation:

CONCRETE PAVER FINISH COAT - Please refer to the ICPI Tech Spec # 5 to determine the correct cleaningprocedures and product choice for sealing pavers in variable environments. This is available @ www.icpi.org, or contact your local ICPI chapter.For new pavers no preparation is necessary other than removing any dirt, efflorescence, or sand. For older paversthe surface must be free from dirt, grease and mildew. Scrub with detergent or treat with bleach as needed and rinse thoroughly. If the pavers have been previously sealed, special caution must be taken to insure that Paver Sealerwill adhere to the old sealer. Paver Sealer will adhere to most acrylic sealers, but may not adhere to polyurethane orsilicate type sealers. Contact the previous installer to find out what type of sealer was used or try a test area. Call your dealer or TUF-TOP for help if uncertain. All surfaces must be clean and dry.

BARE CONCRETE DRIVEWAYS & WALKS - Concrete should be clean, dry, and free from grease,oil, and previous coatings. Pressure washing is recommended. Will adhere over most acrylic sealers. A test patch is recommended to check for adhesion or compatibility.

SPRAY DECK - For newly applied Spray Deck, no preparation is necessary other than removing any dirt,efflorescence, and loose material. The surface must be completely dry, and have a pH or 10.5 or less or "blushing" / poor adhesion may occur.

Paver LV may be tinted with up to 2 fluid. oz. per gallon with Industrial Tints to achieve a Antique or highlightedeffect.

Application:

DO NOT APPLY if rain or heavy dew are forecast within 24 hours of application. Moisture will call coating to "blush" if not full cured before exposure. Low temperatures and high humidity will lengthen cure time.

APPLY in thin coats, allowing at least 2 hours between coats with no more than 4 coats in a 24 hour period to guard against solvent trapping.

CONCRETE "PAVER" FINISH COAT - Apply with roller, brush, or airless, conventional spray equipment.For most applications, two coats are preferred. Apply first coat, allow to dry a minimum of 6 hours depending on weather, and apply second coat. For best results do not dilute. Allow overnight drying for light foot traffic and 48-72 hours before allowing vehicle traffic.

Limitations:

  • DO NOT APPLY when air or surface temperatures are below 50 degrees Fahrenheit ( 10 C ) or are expected to fallthere before the coating can dry.
  • DO NOT APPLY to a wet or damp surface
  • DO NOT APPLY when it may rain or if dew may condense on the surface before PAVER SHIELD 260 will have a chance to dry.
  • NOT FOR USE on STAMPED CONCRETE!
  • NOT FOR USE on FIRED BRICK, CERAMIC, OR WIRE CUT TILE!
  • DO NOT OVER APPLY! Blushing , crazing, dirt pick-up and tire printing may result.

Drying Time:

Normally dries in 1-3 hours and can be walked on after drying overnight. 48 hours are generally required beforeheavy foot traffic. Low temperatures and high humidity can extend drying and curing time.

Maintenance:

Small scratches may be repaired with a small amount of Xylene and a brush. Apply a small amount of Xylene to the affected area and re-flow the sealer into the scratch. For larger areas or for re-coating, make sure the surfaceis clean, completely dry and free from contaminants. Re-apply a thin, light coat to the wear areas. Lap lines maybe feathered with xylene.